TIBCO iProcess Conductor 11.2.0 HotFix 02 is available.

TIBCO iProcess Conductor 11.2.0 HotFix 02 is available.

book

Article ID: KB0105290

calendar_today

Updated On:

Products Versions
TIBCO iProcess Conductor -
Not Applicable -

Description

Description:
Product Name    : TIBCO iProcess Conductor
Release Version  : 11.2.0-Hotfix02
Release Date     : January 2010
========================================================

This hotfix corrects the issue listed in the Closed Issues section.
It does not include 11.2.0-Hotfix01.

This hotfix applies to TIBCO iProcess Conductor, version 11.2.0
running on the following platforms and database:

  Microsoft Windows (x86):
    - Windows XP Professional
    - Windows Server 2003 SP2
    - Windows Server 2003 x64
    - Windows Server 2008
    - Windows Server 2008 x64
    - Windows Vista SP1

  Linux (x86):
    One of the following Linux versions (using 32-bit JRE libraries
    only):

    - Novell SUSE Linux Enterprise 10
    - RedHat Enterprise Linux 4.x AS
    - RedHat Enterprise Linux 4.x ES
    - RedHat Enterprise Linux 5.x AS
    - RedHat Enterprise Linux 5.x ES

    (Other Linux implementations may be compatible; see the TIBCO
    iProcess Conductor Installation guide.)

  Supported Databases

    - Oracle 10g release 10.2.0.4
    - Oracle 11g release 11.1.0.6

========================================================

Closed Issues in 11.2.0-Hotfix02

Defect Id: MR 42306

  Change the way that iProcess Conductor handles amendments when all
  order lines in an order are set to an action of Cancelled.  

  Implemented. The way iProcess Conductor operates is now as follows:

  If the status of the order is "Execution":

  1. When iProcess Conductor receives an amendment request that sets all
     order lines to an action of Cancelled, the order status is set immediately
     to "Cancel". The amendment is then handled with existing functionality.

  2. Once the EAI Order step in the relevant Process Components has set all
      order lines to Cancelled, the Order status will change to "Cancelled".  

  3. Once the order is in a status of "Cancel" or "Cancelled", any future
     amendment requests are rejected by iProcess Conductor. It is not possible
     to re-activate or amend an order in a state of "Cancel" or "Cancelled".
  
  If the status of the order is prior to "Execution", for example if it is
  "Submitted", "Fesibility", "Feasibility Failed" or
  "Execution Plan Development":

  1. When iProcess Conductor receives an amendment request that sets all
     order lines to an action of Cancelled, the order status is set immediately
     to "Cancelled".

  2. An Ad-hoc event step should be triggered in the fulfilment process to
     withdraw any running steps or sub-processes.

  In either case, the execution plan status is unaffected. It continues
  processing until all tasks are completed.

========================================================

NOTE: See attached Readme document for installation instructions.

========================================================

The TIBCO iProcess Conductor 11.2.0 HotFix 02 can be downloaded from our support-ftp.tibco.com. You will be able to download by clicking on the link below after you provide your TIBCO Support Web username and password in the url:

                     ftp://username:password@support-ftp.tibco.com

Directory path:
available_downloads/StaffwareProcessSuite/iProcess/conductor/11.2.0/hotfix-02
========================================================

Issue/Introduction

TIBCO iProcess Conductor 11.2.0 HotFix 02 is available.

Environment

Product: TIBCO iProcess Conductor Version: 11.2.0 OS: --------------------

Attachments

TIBCO iProcess Conductor 11.2.0 HotFix 02 is available. get_app