TIBCO EMS Transport Channel for WCF 1.1.0 Hotfix2 has been released
book
Article ID: KB0105043
calendar_today
Updated On:
Products
Versions
TIBCO EMS Transport Channel for WCF
-
Not Applicable
-
Description
Description: TIBCO EMS Transport Channel for WCF 1.1.0_hotfix02 has been released.
You can download this hotfix2 from the TIBCO Product Support FTP server using your eSupport username and password, at "ftp:// ftp.tibco.com/available_downloads/ActiveEnterprise/Messaging/TEMS/1.1.0/Hotfix_2".
This hotfix is cumulative with all previous 1.1.0.x hotfixes.
================================================================================ The following files were changed in this hotfix:
- TIBCO.EMS.WCF.dll
================================================================================ Closed Issues in 1.1.0_Hotfix02
Defect Id: 1-AXUCJR When the following EMS fault tolerance exception setting is set to true in the context of a TIBCO EMS Transport:
Tibems.SetExceptionOnFTSwitch(true);
and a fault-tolerant EMS server switch over (i.e., 7222 >> 7224) takes place, this results in an exception event that causes the TIBCO EMS Transport to abort the channel.
Corrected. The exception is now caught and logged, and the channel is allowed to continue normally.
Closed Issues in 1.1.0_Hotfix01
Defect Id: 1-9GVGYF Duplex MEP throws a null reference exception.
Corrected.
Defect Id: 1-ACYUU7 Message sizes are limited to 1MB when running under WAS. The maximum message size should be set by the maxReceivedMessageSize parameter in the web.config file (up to 4GB maximum).
To install this hotfix, you must install the included TIBCO.EMS.WCF.dll file into the Global Assembly Cache (GAC). This is done by "dragging and dropping" the included TIBCO.EMS.WCF.dll file into the C:\Windows\assembly folder. The assembly folder is a special folder where the .NET Framework stores assemblies for the GAC. (Note you must drag and drop the file into the assembly folder -- you cannot copy it.)
Also note that any other referenced instance of the old TIBCO.EMS.WCF.dll file should also be replaced with the new file (if applicable).
Issue/Introduction
TIBCO EMS Transport Channel for WCF 1.1.0 Hotfix2 has been released
Environment
Product: TIBCO EMS Transport Channel for WCF
Version: 1.1.0.2
OS:
--------------------