TIBCO EMS Transport Channel for WCF 1.1.0 Hotfix2 has been released

TIBCO EMS Transport Channel for WCF 1.1.0 Hotfix2 has been released

book

Article ID: KB0105043

calendar_today

Updated On:

Products Versions
TIBCO EMS Transport Channel for WCF -
Not Applicable -

Description

Description:
TIBCO EMS Transport Channel for WCF 1.1.0_hotfix02 has been released.

You can download this hotfix2 from the TIBCO Product Support FTP server using your eSupport username and password, at
"ftp:// ftp.tibco.com/available_downloads/ActiveEnterprise/Messaging/TEMS/1.1.0/Hotfix_2".

This hotfix is cumulative with all previous 1.1.0.x hotfixes.

================================================================================
The following files were changed in this hotfix:

   - TIBCO.EMS.WCF.dll

================================================================================
Closed Issues in 1.1.0_Hotfix02

Defect Id: 1-AXUCJR
  When the following EMS fault tolerance exception setting is set to true in the
  context of a TIBCO EMS Transport:

      Tibems.SetExceptionOnFTSwitch(true);

  and a fault-tolerant EMS server switch over (i.e., 7222 >> 7224) takes place,
  this results in an exception event that causes the TIBCO EMS Transport to
  abort the channel.

  Corrected. The exception is now caught and logged, and the channel is allowed
  to continue normally.


Closed Issues in 1.1.0_Hotfix01

Defect Id: 1-9GVGYF
  Duplex MEP throws a null reference exception.

  Corrected.

Defect Id: 1-ACYUU7
  Message sizes are limited to 1MB when running under WAS. The maximum message
  size should be set by the maxReceivedMessageSize parameter in the web.config
  file (up to 4GB maximum).

  Corrected.

================================================================================
Installation

  To install this hotfix, you must install the included TIBCO.EMS.WCF.dll file
  into the Global Assembly Cache (GAC). This is done by "dragging and dropping"
  the included TIBCO.EMS.WCF.dll file into the C:\Windows\assembly folder. The
  assembly folder is a special folder where the .NET Framework stores assemblies
  for the GAC. (Note you must drag and drop the file into the assembly
  folder -- you cannot copy it.)

  Also note that any other referenced instance of the old TIBCO.EMS.WCF.dll file
  should also be replaced with the new file (if applicable).

Issue/Introduction

TIBCO EMS Transport Channel for WCF 1.1.0 Hotfix2 has been released

Environment

Product: TIBCO EMS Transport Channel for WCF Version: 1.1.0.2 OS: --------------------