TIBCO ActiveFulfillment 1.2.0 Hotfix 08 is now available.

TIBCO ActiveFulfillment 1.2.0 Hotfix 08 is now available.

book

Article ID: KB0104089

calendar_today

Updated On:

Products Versions
TIBCO ActiveFulfillment -
Not Applicable -

Description

Description:
The hotfix can be downloaded from the TIBCO Support ftp server, support-ftp.tibco.com. Please use your eSupport username and password to access the server. After connecting, go to /available_downloads/ActiveFulfillmentFramework/ActiveFulfillment/1.2.0/hotfix-08/  to download the hotfix.
This .tar file also has the Readme file inside. Please untar the file and look for the Readme file for Instruction on how to apply the hotfix.

The defects fixed in AF 1.2.0 Hotfix 08 are:

AF-2260
Milestone implementation was incorrect.

Fixed an issue where the status of the plan item changed from PENDING to
EXECUTION immediately after fulfilling the dependency for an intermediate
milestone. With this fix, the plan item status changes from PENDING to EXECUTION
only after the dependency on its START milestone is fulfilled.

AF-2203
The LinkId worked inconsistently.

AF-2104
While generating the AOPD plan, the “java.lang.OutOfMemoryError: Java heap space”
error was reported on invoking the same order again.

AF-2103
AffinityCorrelation for Conditional Affinity did not work as per specifications.

AF-2085
The Withdraw order Web service in OMS did not work for orders with amendments in the
incomplete state.

AF-2068  
The 'requiredByDate' element specified only at the order header level, was ignored
in AOPD while generating the execution plan.

AF-2067  
GetOrderDetails SOAP operation, when used against the OMS server, did not
deserialize the SOAP envelope for some Orders.

AF-2064
ProductDependsOn relationship did not show the sequenceDirection relationship
attribute.

The 'sequenceDirection' relationship attribute with valid values “BEFORE” or
“AFTER” is now added in the ProductDependsOn relationship. The
sequenceDirection relationship attribute is specified for each sourceAction
and targetAction pair. Specify:
- “BEFORE”  to sequence the sourceAction before the targetAction.
- “AFTER”  to sequence the  sourceAction after the targetAction.

AF-2050
Sequencing did not work as per specifications.

AF-2049
Memory leak was discovered in the Orchestrator agent.

The SetPlanOMSEvent references in the Orchestrator agent did not clean up as per
heap dump analysis. This led to the Orchestrator agent going Out of Memory after
sometime, depending on the order load.

This fix will clean up the SetPlanOMSEvent instances and prevent the
Orchestrator going out of memory.

Issue/Introduction

TIBCO ActiveFulfillment 1.2.0 Hotfix 08 is now available.

Environment

Product: TIBCO ActiveFulfillment Version: 1.2.0 OS: --------------------