PD-2571 When a Governance Control had an unfulfilled Shared Resource dependency with the Governed Objects in a Deployable state, no corresponding error message was displayed to the user.
PD-2503 When TIBCO ActiveMatrix Policy Director Administration Server was created using the TIBCO Configuration Tool, the string,'[null' for null was uninformative in the option - Create a TIBCO ActiveMatrix Policy Director Administrator Server.
GWS-371 Policy Director was unable to create proxy applications when WSDLs contained header declarations.
PD-2433 TIBCO ActiveMatrix Policy Director did not support EMS over SSL for communication between the Distribution Engine and the Governance Agent for TIBCO ActiveMatrix BusinessWorks.This issue will now be resolved by performing the following steps:
1. Use TIBCO Configuration Tool to configure the parameters for EMS over SSL parameters for Distribution Engine and the Governance Agent for TIBCO ActiveMatrix BusinessWorks. 2. Update the ActiveMatrix BusinessWorks Engine TRA file to include the following java property:java.property.TIBCO_SECURITY_VENDOR=j2se.
PD-2722 Registering an external WSDL was unresponsive when the file size was over 1 MB.
PD-2602 When ActiveMatrix Policy Director was installed on an ActiveMatrix 3.2 server, TIBCO Configuration Tool did not provide an option to configure JNDI Connection Resource. The connection Resource helped communicate with the Governance Agent for TIBCO ActiveMatrix BusinessWorks.
PD-2666 On an ActiveMatrix 3.2 server, ActiveMatrix Policy Director installation failed when it was configured with a non-default enterprise and instanceName.
PD-2648 When Policy Director was configured using the TIBCO Configuration Tool, the TIBCOHOST configuration folder was incorrectly displayed as an editable field containing config.home as the default value.
PD-2645 Policy enforcement failed when a proxy application, on which a policy was being enforced, was redeployed on multiple nodes.
PD-2853 The SSL setup for the EMS configuration of the Governance Agent for TIBCO ActiveMatrix BusinessWorks no longer offers PKCS12 for the trust store. PKCS12 is used to store private keys and not certificates.
PD-2707 Fixed a defect that caused the WSS Consumer policy CLI to incorrectly pick the default encryption algorithms. ================================================================================
Issue/Introduction
TIBCO ActiveMatrix(R) Policy Director 1.0.0 Hotfix, TIB_pd_1.0.0_hotfix001, is now available.
Environment
Product: TIBCO ActiveMatrix Policy Director
Version: 1.0.0
OS: All
--------------------
Attachments
TIBCO ActiveMatrix(R) Policy Director 1.0.0 Hotfix, TIB_pd_1.0.0_hotfix001, is now available.
get_app