Dear GridServer Users,

We just released HF-18 for GridServer 5.1.2.

Closed Issues in 5.1.2_hotfix018(This Release)

Communication and Network

GS-11940

If an Engine was logged off and then logged into a Broker while a heartbeat was in progress, it was possible for that heartbeat to fail and cause the Engine to log off again. Now any heartbeat failure due to a connection being closed no longer results in a logoff.

Documentation

GS-11806

Errors in the hotfix uninstall procedure in the readme were corrected.

PDriver

GS-11713

On very rare occasions, string output from PDriver tasks would get truncated due to a string corruption issue. This has only been observed on Solaris Sparc Engines, but in theory it could happen on others.

Stability,Fault Tolerance

GS-11852

When using Collect Later/Never Services, the folders in the 'dataTransfer' directory were not completely removed when the Service completed.