Products | Versions |
---|---|
TIBCO RTView - EMS Monitor System | - |
Not Applicable | - |
Description:
-------------------- HOTFIX -----------------------------------------------
TIBCO RTView Version: 6.2.4.1, 09 June 2014
Also
TIBCO RTView EMS Monitoring System Version 6.3.0.1, 26 June 2014
---------------------------------------------------------------------------
Compatability:
--------------
TIBCO RTView EMS Monitor System Version: 6.3.0.0
TIBCO RTView BusinessWorks Monitoring System Version: 6.1.0.0
Contents:
----------
README_Hotfix_6.2.4.1.txt
rtview/lib/gmsjrtview.jar
rtview/lib/gmsjrtvhistorian.jar
rtview/lib/gmsjrtvbuild.jar
Installation:
-------------
1. Create a backup copy of your existing installation.
2. Extract the .zip into RTVAPM_HOME\rtview\lib.
Release Notes
--------------
19363: Fixed memory leak for cache attachment with column filter
A memory leak has been fixed in the cache data source. The leak occurs if
there is a data attachment to the current table of a cache, and the data
attachment specifies a column filter but no row filter, and rows are never
or only very rarely removed from the cache. If there is such a data attachment
the data server will leak memory each time the cache is updated. The size of
the leak depends on the number of columns specified in the filter.
=======================================================
NOTE: See Readme document on the download site for installation instructions.
=======================================================
The Hotfix and Readme can be downloaded from the TIBCO Product Support file transfer server,
mft.tibco.com, using your username and password for the TIBCO Support Central website.
Please note you should use an FTP or SFTP client or command-line FTP.
TIBCO employees must use a secure protocol.
Server name: mft.tibco.com
Credentials: use your TSC (TIBCO Support Central website) login.
Browser: https://mft.tibco.com
FTP: port 21
SFTP: port 22
Once you have successfully logged into the server, you will find the hotfix package under the following location: /AvailableDownloads/RTview/EMSmonitor/6.3.0/hotfix-1