Description: Affected File TIBCO Silver(R) Fabric Enabler for TIBCO BusinessEvents(TM) 2.5.0 HF001
The following file needs to be installed by this hotfix:
SilverFabric_be_container_2.5.0_HF001_gridlib.zip
Note: This hotfix is not platform specific.
=========================================================================================
Closed Issues for SFBE 2.5.0 HF001
TIBCO Silver(R) Fabric Enabler for ActiveMatrix BusinessEvents(TM) 2.5.0 HF001 corrects
and closes the following issues:
SFBE-234 (Customer reported 497044) When using a domain with EMS transport,
if the EMS Server is down, archives are not reported, the virtual router
for HTTP endpoints are removed.
SFBE-228 (Customer reported 486876) Empty folders under Application Management
in TIBCO administrator GUI gets deleted when BE component is shutdown
- If the runtime variable CLEANUP_EMPTY_DIRECTORY_ON_SHUTDOWN is created and set to
false, empty directories will not be deleted on BW component shutdown.
- If the runtime variable CLEANUP_EMPTY_DIRECTORY_ON_SHUTDOWN is not created or set to
true, the current behavior will be the same : Empty directories will be deleted.
SFBE-227 (Customer reported 478882) Full stops/periods "." in the Application name
are replaced with "2E" and prevent deployment and archive scaling to happen correctly
SFBE-229 (Customer reported 474941) Value of the property ‘application.start.dir’
in application tra file is changed un-correctly when a BEcomponent is restarted
with FAST TLM restart option.
SFBE-230 (customer reported 464356 ) Archive scaling keeps scaling up
forever and never scale down.
SFBE-217 - When an application name contains folders, when deploying using REST
on 2 different TLM it will generate a wrong application name.