Description: Hotfix CZ02021 can be downloaded from the TIBCO Support Managed File Transfer Server- mft.tibco.com.
Server name: mft.tibco.com
Credentials: Use your TSC (TIBCO Support Central website) login.
Browser: https://mft.tibco.com
FTP: port 21
SFTP: port 22
Once logged on you can find the hotfix under "/AvailableDownloads/MFT/PlatformServer/zOS/7.2.0"
The .zip file has the Readme file inside. Please unzip the file and review the Readme file for instructions on how to apply the hotfix.
CZ02021 is a cumulative hotfix that resolves defects and includes defects resolved in prior hotfixes. It supersedes all prior hotfixes for release 7.2.0.
Note: Issue PSZ-209 changes way that BLKSIZE is set for a new TAPE file:
: RECFM=FB - BLKSIZE was set to LRECL
: RECFM=VB - BLKSIZE was set to LRECL+4
After this fix, zOS sets the BLKSIZE to a more efficient value
Defects fixed in CZ02021:
PSZ-255 When a Responder Transfer fails with an SSL error, the transfer
is not removed from the works queue and no Audit record is written
PSZ-254 Receive 002-4 abend when sending a RECFM=VBS LRECL=32768 Tape file
and MAINTAINBDW=BLOCKVS is not specified
PSZ-252 When ENQ_ENTIRE_TRANSFER is set to YES, ENQ is not executed properly
when two files with the same DSN are created at the same time
PSZ-251 Trailing spaces are not removed when using a local translation
table.
PSZ-245 The Blocksize changes when sending a VBS file from tape to disk and
BLOCKVS is specified. When writing to disk, MFT will allow zOS to
set the optimum blocksize unless the BLKSIZE parameter is defined.
Prior to this change, the BLKSIZE parameter was ignored by the
receiving platform. When sending a VBS tape with
MAINTAINBDW=BLOCKVS, the tape BLKSIZE will be used when creating the
disk dataset. This change also allows the BLKSIZE to be set
manually without specifying the RECFM and LRECL.
PSZ-244 Cannot access files on multi-dataset tapes when the file is not
the first dataset on the tape. The following new batch
parameters have been added:
LOCALLABEL=(nn,SL)
REMOTELABEL=(nn,SL)
Where NN is the file label number. "SL" is the only label type
currently supported.
Note: For Sending a tape file, if the label information is in the
catalog, this parameter is not required.
Note: This parameter will be ignored for disk files.
PSZ-243 Platform Server for zOS cannot restrict the TLS Versions supported.
The following new GLOBAL Parameter was added:
TLSENABLEDPROTOCOLS={ All|TLSV1,TLSV1_1,TLSV1_2 }
Multiple "TLS" parameters can be entered separated by a comma.
If this parameter is not entered, the default is "All".
Example: TLSENABLEDPROTOCOLS=TLSV1_1,TLSV1_2
PSZ-242 When the CFPING command is executed without a host name, the
request fails with an 0C4 abend. The same abend is received when
space is entered before the hostname.
Defects fixed in CZ02019:
PSZ-239 Received S0C4 in OSISBIDF+1504 when started task is coming up
PSZ-238 When User Profile contains a domain, the remote user can be
corrupted
PSZ-237 When ENQ_ENTIRE_TRANSFER is set to YES, ENQ is not executed
properly when file is created
PSZ-236 Batch transfers queued with DATE and TIME set are purged from the
queue instead of being executed
PSZ-235 BOSSID should be checked when user tries to issue ISPF or REXX
INITHOLD, INITREL, RESPHOLD or RESPREL requests
PSZ-234 When the GLOBAL EXPIRE parameter is set to 999, the expiration
date is set incorrectly to an invalid date. Example: 2017644
PSZ-200 When Command Center specifies Compression Values of NO or NEVER
Platform Server will create node entries with incorrect values
Defects fixed in CZ02017:
PSZ-233 After CZ02004, debugging messages were displayed on the console
PSZ-229 MFT Started Task receives multiple 878 abends when SUBJCL function
is used
PSZ-228 When the "F MFTSTC,RESET,nodename" operator command is executed
and the Node is in an error state, the nodename displayed on the
PGTS0090I message is corrupted
PSZ-227 MFT PS received error on FUSUTIL DELETE or RENAME when dataset is
on an Extended Attribute Volume and has a DSCB8
PGTE3832E FUSUTIL RENAME OBTAIN Error: UNKNOWN CAMLST RETURN CODE
ENCOUNTERED - RC=24 Reason=0000000
Defects fixed in CZ02011:
PSZ-220 Received message: "PGTS0023I LOG Slot full ...": OSIMSG Stopped
recording messages and Audit records are no longer written
PSZ-215 TRNWAIT function fails when running in the STC under cross memory
PSZ-214 Resolved abend 0C4 in module FUSAUDTB+DC8
PSZ-212 MFT issues ENQ to the base GDG, and when it fails shows a
none-retryable RC=8 instead of RC=4
Defects fixed in CZ02004:
PSZ-209 When creating a new TAPE file, the BLKSIZE is set too low when
RECFM=FB or RECFM=VB. Code changed to let zOS set the BLKSIZE
PSZ-208 When Global ENQ_ENTIRE_TRANSFER=YES, "File in Use" is not treated
as a temporary file error
PSZ-207 MFTPS v7.2 z/OS (CZ02002) encounters a 0E0 dump at DNIQUEUE+1AB6
when attempting to perform a DNI transfer with a wildcard of HFS
files.
PSZ-206 Batch Script executing with Hotfix CZ01998 loops when RC != 0
and PROCESS statement (i.e. Transfer) is executed
PSZ-205 Intermittent 0E0 abend in module OSIADIR0 at offset 000045EE
PSZ-203 When performing a directory receive from Windows and no files
are returned by Windows, the following can occur:
: Recursively executing Receive directory commands
: Abend 0C4 followed by Abend 0C1 can occur
PSZ-199 Abend 0C4 received when restarting on a multi-volume dataset
and the restart volume is not the first volume
PSZ-196 Issuing the TCPTROF Operator Command can cause a S0C1 Abend
PSZ-195 Display the slot number on PGTS0825I message when the audit file
is full
PSZ-194 When a transfer fails with an ENQ failure, display messages
showing the job holding the ENQ
PSZ-193 Command Center Non-Event Processing for Platform Server will
not work when Platform Server time is is a different time zone
or has a different system time
Note: The Command Center Non-Event feature is implemented in
MFT Command Center 7.3
PSZ-190 Command Center requests initiated using SSL do not work
PSZ-187 Change duplicate message PGTB4148E to PGTB4199E
Defects fixed in CZ02002:
PSZ-185 Receive INITAPI Error 00156 when a user without an OMVS segment
initiates a TAPE Send and the Target node is an IPName
PSZ-184 All log entries are not printed when you issue the LOGSNAP
operator command
PSZ-181 Directory list request does not return all files
PSZ-180 FUSPROF: More than 2000 entries cannot be listed
Added new FUSPROF parameter:
MAX#=nnnnn Alias (MAX#RETURNED)
This parameter defines the maximum number of profiles
that will be returned for a REQUEST=LIST operation.
Valid Values are: 0-99999
When 0 is defined, or if the parameter is not defined, the
default value of 2000 is used.
PSZ-169 MFT PS for z/OS Started Task failed to shutdown after QUIESCE
command entered.
Defects fixed in CZ01998:
PSZ-178 Transfer displays message PGTM7352E accessing a zOS high level
alias. This message will no longer be displayed for aliases.
PSZ-177 Resolve 0E0 abend in DNIQUEUE+757C when AR15 is corrupted.
PSZ-174 When more than one IPname is associated with an IP address,
incoming requests may fail with node not found.
Added new GLOBAL parameter:
FIND_NODE_COMPATIBILITY={YES|NO}
This parameter determines the mechanism for finding a Node
definition for incoming requests. In MFT 7.2 and above, the code
uses a reverse DNS lookup to match the incoming request to a Node
definition; prior releases used a one-time DNS request to match the
incoming request to a Node definition. The default value of this
parameter is "NO".
Yes: Use both methods to match an incoming request to a Node
definition. Both the reverse DNS lookup and the DNS lookup
will be used.
No: Only the reverse DNS look will be used to match an incoming
request to a Node definition. This is the default value.
PSZ-173 Change script program (OSIUC000) to not call batch program
(OSIUB000) if there was a bad parameter in a script.
PSZ-171 Recompiled Scripting interface program (OSIUC000) to support
LONGPARM(YES). Up to 4096 bytes of PARM information will
be supported.
PSZ-167 The MFTPS v7.2 z/OS FIPSJCL job stream displays incorrect
unauthorized message: FIPS140 -2 Not Authorized: Bypassing
CPU ID and CPU Type display.
Defects fixed in CZ01996:
PSZ-170 When receiving a loadlib from a zOS system, the transfer may go
into a loop. Another symptom is that under rare circumstances
the last byte of a file may be corrupted.
Defects fixed in CZ01988:
PSZ-163 MFTPS z/OS LRECL of 32768 not maintained when MAINTAINBDW=BlocksVS
is specified and the RECFM=VBS and the LRECL=32768.
PSZ-162 When Command Center sends a Node or Transfer Request to zOS and
the Port is less than 5 characters, the request will fail.
PSZ-161 Transfers will fail when the LRECL is maxed when MAINTAINRDW
is used.
PSZ-159 A user with no access to the MFT Facility can see another users
transaction and details through the ISPF panels using TCPIP.
Defects fixed in CZ01977:
PSZ-154 When using an FTP, SSH or Browser client to connect to IS directory
download from backend PS z/OS, if the date created is not available
then the date created from the prior dataset is passed back to IS.
PSZ-146 Resolves a problem with VBS datasets containing logical
records with a length greater than 32K.
Added New Transfer sub-parameter:
MAINTAINBDW=BLOCKVS
When sending VBS dataset with records greater than 32K an 002-4
abend is received when this parameter is not set. This parameter
is ignored when RECFM is not VS or VBS.
PSZ-141 MFTPS outbound transfers became hung as a result of a SYSDSN ENQ
deadlock between the file transfer and the Post Processing Actions
Added New GLOBAL Parameter:
ENQ_ENTIRE_TRANSFER={YES|NO)
This defines whether the entire transfer will be enqueued,
including Post Processing Actions (PPA). Valid Values:
NO This is the default value. MFT will use SYSDSN ENQ to
limit access to files while the files are allocated
YES MFT will ENQ the file being transferred for the life
of the transfer, including Post Processing Actions