Create the Taskset 1. Open Statistica Enterprise Manager
2. Go to the Monitoring and Alerting Server icon, right-click on Server Task Sets, and select "New taskset" as shown below and attach to a system view folder of choice. Alternatively, you may select a system folder of choice and choose "New Taskset".
3. Name the taskset as per your choice. For this example, we are calling it "Cyclone".
4. Click the "Add Task" button and select the analysis of choice (Using cyclone for this example, that was created via article :
https://support.tibco.com/s/article/How-to-create-an-IQC-Chart-in-Statistica-Enterprise ) :
5. Select to check alarms for both characteristics:
6. Click "View/Edit Alarm Options" button, select "Sample out of control", and click the "Commit" button. Enter a change reason, if enabled:
7. Go back to the Cyclone taskset and click the "Attach..." button. Attach to the System View folder of choice and click "Commit" button. You can skip this step if you chose the alternate method of choosing the folder in Step 2 above.
9. Add an Alarm Rule and configure to execute to send an email if any conditions are met:
10. Go to Options to "Set Alarms and rules", and add Admin email address In this example, we uncheck both "Use alarms not older than:..." and "Process alarm rules against new alarms only". Finally, click "Commit" button:
Create an Alarm Dashboard 1. Right-click on Dashboard Alarm Admin, select "New Alarm Dashboard". Alternatively, you may select a system folder of choice and choose "New Alarm Dashboard"
2. Name the Alarm Dashboard of your choice. In this example, we are naming it "Cyclone":
3. Add a row to the dashboard:
4. Select the dashboard and click the "Attach..." button. Attach to the System View folder of choice. You may skip doing this if you chose to create a dashboard under a system view folder in Step 1.
5. Define Access permissions, and click "Commit" button as shown below
Test Taskset 1. Select the Alarm Dashboard to test
2. Right-click on the taskset and select "Submit Taskset":
3. The dashboard will show as Red when samples are out of control:
4. An email will be sent with the alarm information provided the SMTP information is configured as detailed in :
https://support.tibco.com/s/article/How-to-configure-Enterprise-manager-for-alarm-emails-and-Job-emails